-Polarization Maintaining DWDM-
| Features | 
| Low insertion loss | 
| High wavelength isolation | 
| Low polarization dependence | 
| Environmentally stable | 
| Applications | 
| DWDM systems | 
| Fiber optic sensors | 
| ADD or DROP Function | 
| Specifications (PM DWDM) | 
| Parameter | Units | |||||
| Filter Type | 200 | 100 | GHz | |||
| Start Wavelength | ITU Grid | nm | ||||
| Channel Passband | Bandwidth @0.5dB | Min. | 0.5 | 0.2 | nm | |
| Typ. | 0.7 | 0.4 | nm | |||
| Insertion Loss@C to P | Max. | 1.0 | 1.2 | dB | ||
| Typ. | 0.8 | 1.0 | dB | |||
| Channel Isolation @C to P | Min. | 25 | dB | |||
| Typ. | 30 | dB | ||||
| Reflection Band | Insertion Loss @C to R | Max. | 0.5 | dB | ||
| Typ. | 0.3 | dB | ||||
| Channel Isolation @C to R | Min. | 12 | dB | |||
| Typ. | 15 | dB | ||||
| Extinction Ratio @23 ºC | Min. | 20 | dB | |||
| Typ. | 22 | dB | ||||
| Directivity | Min. | 50 | dB | |||
| Return Loss | Min. | 50 | dB | |||
| Optical Power | Max. | 300 | mW | |||
| Start Wavelength Stability | <= 0.002 | nm/ºC | ||||
| Thermal Stability | <= 0.005 | dB/ºC | ||||
| Tensile Load | Max. | 5 | N | |||
| Fiber Type | PM Panda Fiber | -- | ||||
| Operating Temperature | -5 to 70 | ºC | ||||
| Storage Temperature | -40 to 85 | ºC | ||||
| * The specification is for the PM DWDM without connector. * For Devices with Connectors, IL will be 0.3dB higher, RL will be 5dB lower, ER will be 2dB lower. | 
| For customized specification on the PM DWDM, please contact us at contact@optolinkcorp.com. | 
| Ordering Codes | 
| OLDWDM - P - [Channel Spacing] - [Channel Number] - [Start Wavelength] - [Fiber Type ] - [Fiber Length] - [Connector Type] - [Application Type] | 
| Channel Spacing | Code | 
		Channel Number | Code | 
		Start Wavelength | Code | Fiber Type  | Code | Fiber Length  | Code | Connector Type | Code | 
		Application Type | Code | 
| 100GHz | 1 | 2 channels | 02 | ITU Grid | XX | 250um Panda Fiber | 25 | 0.75m | 75 | 
		No Connector | 
		NC | 
		MUX | M | 
| 200GHz | 2 | 4 channels | 04 | 400um Panda Fiber | 40 | Others | XX | 
		FC/APC | 
		FA | 
		DEMUX | D | ||
| 8 channels | 08 | 900um Loose Tube | 90 | 
		FC/PC | 
		FP | 
		MUX and DEMUX | MD | ||||||
| 16 channels | 16 | Others | XX | 
		FC/UPC | 
		FU | ||||||||
| 20 channels | 20 | 
		SC/APC | 
		SA | ||||||||||
| 32 channels | 32 | 
		SC/PC | 
		SP | ||||||||||
| 40 channels | 40 | 
		ST/UPC | 
		ST | ||||||||||
| 
		SC/UPC | 
		SU | ||||||||||||
| 
		LC/PC | 
		LP | ||||||||||||
| 
		LC/UPC | 
		LU | ||||||||||||
| 
		MU/PC | 
		MP | ||||||||||||
| * Opto-Link Corporation Ltd reserves the right to make changes to the PM DWDM without notice. | 
| 
 | |||
| 
 | |||
| © Opto-Link Corporation Limited 2002-2012. All Rights Reserved. | |||