
| Features | 
| Low insertion loss | 
| High channel isolation | 
| Low polarization dependence | 
| Environmentally stable | 
| Applications | 
| DWDM systems | 
| Fiber optic sensors | 
| Subscriber loop | 
| CATV | 
| Specifications (DWDM) | 
| Dense Wavelength Division Multiplexer (100GHz) | 
| 
        
        
        
       Parameter  | 
      Channel Number   | 
        Units  | 
    ||||||
| Channel Number | 2  | 
      4  | 
      8  | 
      16  | 
      32  | 
      40  | 
      ||
| Start Wavelength |  ITU-T Grid  | 
      nm  | 
    ||||||
| Passband | Central Wavelength +/-0.11   | 
      GHz  | 
    ||||||
| Channel Passband | Min. | 0.25  | 
      nm  | 
    |||||
| Passband Flatness | Max. | 0.5  | 
      dB  | 
    |||||
| Insertion Loss | Typ. | 1.4  | 
      1.6  | 
      2.6  | 
      3.8  | 
      4.8  | 
      5.2  | 
      dB  | 
    
| Max. | 1.8  | 
      2.0  | 
      3.2  | 
      4.5  | 
      5.5  | 
      6.0  | 
      dB  | 
    |
| PDL | Max. | 0.10  | 
      0.15  | 
      0.20  | 
      0.25  | 
      0.30  | 
      0.30  | 
      dB  | 
    
| PMD | Max. | 0.10  | 
      0.15  | 
      ps  | 
    ||||
| Directivity | Min. |  50  | 
      dB  | 
    |||||
| Adjacent Channel Isolation | Min. | 25  | 
      dB  | 
    |||||
| Non-adjacent Channel Isolation | Min. | 45  | 
      dB  | 
    |||||
| Return Loss | Min. | 45  | 
      dB  | 
    |||||
| Wavelength Thermal Stability | Max. | 0.001  | 
      nm/ºC  | 
    |||||
| Insertion Loss Thermal Stability | Max. | 0.005  | 
      0.007  | 
      0.008  | 
      dB/ºC  | 
    |||
| Operation Temperature | -5 to +65  | 
      ºC  | 
    ||||||
| Storage Temperature | -40 to +85  | 
      ºC  | 
    ||||||
| Dense Wavelength Division Multiplexer (200GHz) | 
| 
        
        
        
           Parameter  | 
      Channel Number   | 
      
         Units  | 
    |||||
| Channel Number | 2  | 
      4  | 
      8  | 
      16  | 
      20  | 
      ||
| Start Wavelength |  ITU-T Grid  | 
      nm  | 
    |||||
| Passband | Central Wavelength +/-0.25  | 
      GHz  | 
    |||||
| Channel Passband | Min. | 0.6  | 
      nm  | 
    ||||
| Passband Flatness | Max. | 0.5  | 
      dB  | 
    ||||
| Insertion Loss | Typ. | 1.4  | 
      1.6  | 
      2.6  | 
      3.8  | 
      4.3  | 
      dB  | 
    
| Max. | 1.8  | 
      2.0  | 
      3.2  | 
      4.5  | 
      5.0  | 
      dB  | 
    |
| PDL | Max. | 0.10  | 
      0.15  | 
      0.20  | 
      0.25          | 
      dB  | 
    |
| PMD | Max. | 0.10  | 
      0.15  | 
      ps  | 
    |||
| Directivity | Min. |  50  | 
      dB  | 
    ||||
| Adjacent Channel Isolation | Min. | 25  | 
      dB  | 
    ||||
| Non-adjacent Channel Isolation | Min. | 45  | 
      dB  | 
    ||||
| Return Loss | Min. | 45  | 
      dB  | 
    ||||
| Wavelength Thermal Stability | Max. | 0.002  | 
      nm/ºC  | 
    ||||
| Insertion Loss Thermal Stability | Max. | 0.005  | 
      0.007  | 
      0.008  | 
      dB/ºC  | 
    ||
| Operation Temperature | -5 to +65  | 
      ºC  | 
    |||||
| Storage Temperature | -40 to +85  | 
      ºC  | 
    |||||
* The specification is for the DWDM without connector.  | 
	
| For customized specification on the DWDM, please contact us at contact@optolinkcorp.com. | 
| Ordering Codes | 
OLDWDM - SD -[Channel Spacing] - [Channel Number] - [Start Wavelength] - [Pigtail Length] - [Connector Type]-[Application Type]  | 
    
| Channel Spacing | Code | Channel Number | Code | Start wavelength | Code | Pigtail Length | Code | Connector Type | Code | Application Type | Code | 
| 100GHz | 1 | 2 channels | 02 | ITU Grid | XX | Customer Specify | XX | 
		No Connector  | 
      
		NC  | 
      MUX | M | 
| 200GHz | 2 | 4 channels | 04 | 
		FC/APC  | 
      
		FA  | 
      DEMUX | D | ||||
| 8 channels | 08 | 
		FC/PC  | 
      
		FP  | 
      MUX and DEMUX | M/D | ||||||
| 16 channels | 16 | 
		FC/UPC  | 
      
		FU  | 
      ||||||||
| 20 channels | 20 | 
		SC/APC  | 
      
		SA  | 
    ||||||||
| 32 channels | 32 | 
		SC/PC  | 
      
		SP  | 
    ||||||||
| 40 channels | 40 | 
		ST/UPC  | 
      
		ST  | 
    ||||||||
		SC/UPC  | 
      
		SU  | 
    ||||||||||
		LC/PC  | 
      
		LP  | 
    ||||||||||
		LC/UPC  | 
      
		LU  | 
    ||||||||||
		MU/PC  | 
      
		MP  | 
    ||||||||||
| * Opto-Link Corporation Ltd reserves the right to make changes to the DWDM without notice. | 
  | 
  |||
  | 
  |||
© Opto-Link Corporation Limited 2002-2012. All Rights Reserved.  | 
  |||